null

INOVONICS | EN5040-T EchoStream High Power Repeater with Transformer, 902-928 MHz

Brand: Inovonics

No reviews yet Write a Review
SKU:
EN5040-T
$444.14
$444.14

Product Info / Related Information

Technology:
902-928MHz
Product Type:
Repeater
Features:
120 VAC Transformer
Features:
Tamper-Resistant
Features:
Battery Backup
Weight:
1.00 LBS
Brand:
Inovonics

INOVONICS | EN5040-T EchoStream High Power Repeater with Transformer, 902-928 MHz

Brand: Inovonics

No reviews yet Write a Review
SKU:
EN5040-T
$444.14

Description

Inovonics EN5040-T EchoStream High-Power Repeater w/ Transformer | 902–928 MHz

The Inovonics EN5040-T EchoStream® High-Power Repeater with Transformer extends wireless coverage by receiving, decoding, and retransmitting valid EchoStream messages at enhanced power. Supplied with the required transformer and a rechargeable backup battery, the EN5040-T provides a complete repeater solution for professionally designed commercial security systems.

Designed for multi-floor buildings, shopping centers, warehouses, healthcare facilities, schools, campuses, multi-building properties, and other large installations, the repeater helps wireless signals travel around structural obstacles and across extended distances. Multiple EN5040 Series repeaters can be layered throughout a system to build redundant transmission paths and expand coverage as the facility grows.

Operating within the North American 902–928 MHz frequency range, the EN5040-T supports broadcast and directed EchoStream messaging. It supervises for low battery, loss of line power, case tamper, wall tamper, and RF-jamming conditions while providing approximately 24 hours of typical backup-battery operation.

Transformer Included: Unlike the standard EN5040, the EN5040-T includes the required Class 2 power transformer. This makes it the appropriate transformer-equipped model for qualifying commercial security installations.

UL 2560 Ordering Notice: The EN5040-T sends supervised check-in messages every three minutes. For qualifying UL 2560 emergency-call systems requiring a 20-minute repeater check-in, review the EN5040-20T and verify the complete system configuration.

Key Features and Benefits

  • Extends EchoStream coverage: Receives, decodes, and retransmits valid Inovonics wireless messages at enhanced power.
  • Transformer included: Supplied with the required power transformer for a complete repeater package.
  • Rechargeable backup battery: Provides approximately 24 hours of typical operation during a power interruption.
  • Scalable system design: Multiple repeaters can be layered to cover large facilities, multiple floors, and separate buildings.
  • Redundant RF paths: Properly positioned repeaters can create alternative routes around temporary wireless obstructions.
  • Signal management: Repeats valid EchoStream transmissions while intelligently ignoring unrelated background noise.
  • Two messaging modes: Supports broadcast and directed EchoStream network configurations.
  • Supervised operation: Reports low battery, AC power loss, tamper, RF jamming, and missed check-in conditions.
  • Case and wall tamper: Helps detect unauthorized opening or removal of the repeater.
  • Diagnostic LEDs: Provides visual indicators for decoding, transmitting, low battery, line power, and battery operation.

Technical Specifications

Manufacturer Inovonics Wireless Corporation
Model EN5040-T
Product Type High-power repeater with transformer
Wireless Platform Inovonics EchoStream®
North American Frequency 902–928 MHz
Wireless Technology Frequency-hopping spread spectrum
Messaging Modes Broadcast or directed messaging
Check-In Frequency Every 3 minutes when registered and supervised
Power Requirement 14 VAC, 60 Hz, 250 mA
Power Supply 120 VAC at 20 VA / 12 VAC at 1000 mA
Transformer Included Yes
Backup Battery Rechargeable lithium-ion battery assembly
Battery Capacity 3.6 V; 3250 mAh minimum
Typical Backup Time 24 hours
Housing Dimensions 6.5 × 3.6 × 1.1 in. (165 × 91 × 28 mm)
Weight 7.14 oz. (approximately 202–204 g)
UL Operating Temperature 32°F to 140°F (0°C to 60°C)
Other Installations -4°F to 140°F (-20°C to 60°C)
Operating Humidity Up to 90% relative humidity, non-condensing
Regulatory Certifications Security Level 1 CAN/ULC S304:2016, UL 985, UL 1023 and UL 2610

How the EN5040-T Extends EchoStream Coverage

The EN5040-T listens for valid EchoStream transmissions from compatible wireless devices and other high-power repeaters. After receiving and decoding a recognized message, it retransmits that message at enhanced power so it can reach an EchoStream receiver, gateway, network coordinator, or another repeater.

This process helps wireless signals travel around concrete walls, metal structures, long corridors, multiple floors, and other RF obstacles. Several repeaters can be positioned throughout a property to expand coverage and provide multiple paths between transmitters and the receiving infrastructure.

EN5040-T Package Advantages

Power Transformer

Includes the approved Class 2 transformer required to supply operating power to the repeater.

Backup Battery

Includes a rechargeable lithium-ion backup battery for continued operation during line-power interruptions.

UL Security Certifications

Evaluated to applicable commercial and residential security standards when installed as part of a compliant system.

Diagnostic and Supervision Indicators

Decode LED

Flashes when the repeater receives a recognizable EchoStream RF transmission.

Transmit LED

Illuminates while the EN5040-T retransmits a valid wireless message.

Low-Battery LED

Illuminates when the rechargeable battery is low, disconnected, or no longer operating correctly.

Power LED

Displays green while operating from line power and red while operating from backup battery power.

Repeater Supervision and Trouble Reporting

Although the EN5040-T can begin repeating EchoStream messages after startup, Inovonics strongly recommends registering and supervising every repeater. When supervised, the EN5040-T sends a check-in message every three minutes.

  • Loss of line power
  • Low or failed backup battery
  • Case-tamper condition
  • Wall-tamper condition
  • RF-jamming condition
  • Missed repeater check-in

A missing or inoperative supervised repeater should be reported as a latching trouble condition by the control panel within the time required by the application and applicable standards.

Broadcast and Directed Messaging

Broadcast Messaging

The factory-default setting for conventional EchoStream broadcast networks. The repeater retransmits recognized EchoStream messages received within range.

Directed Messaging

Used with compatible directed-message infrastructure. The installer selects directed mode and configures the network identification through the appropriate gateway.

Recommended Applications

  • Multi-floor commercial buildings
  • Warehouses and distribution centers
  • Shopping malls and retail complexes
  • Schools, colleges, and campuses
  • Hospitals and healthcare facilities
  • Multi-building commercial properties
  • Manufacturing and industrial facilities
  • Long corridors and concrete structures
  • Commercial intrusion and hold-up systems
  • Large EchoStream wireless networks

EchoStream System Compatibility

The EN5040-T can retransmit valid messages from compatible EchoStream transmitters and other high-power repeaters. Current Inovonics literature identifies compatibility with infrastructure including:

  • EN4000 Universal Serial Receiver
  • EN4200 Security-Only Serial Receiver
  • EN4204R Four-Zone Add-On Receiver
  • EN4216MR 16-Zone Receiver
  • EN4232MR 32-Zone Receiver
  • EN7290 Honeywell VISTA Interface
  • Compatible EchoStream gateways
  • Other EN5040 Series repeaters

Compatibility reminder: Confirm receiver support, messaging mode, repeater supervision, network capacity, transmitter type, check-in timing, and applicable regulatory requirements before ordering.

Which EN5040 Series Repeater Do You Need?

Feature EN5040 EN5040-T EN5040-20T
Transformer Included No Yes Yes
Supervised Check-In 3 minutes 3 minutes 20 minutes
UL Status Not evaluated by UL UL 985, UL 1023 and UL 2610 For UL 2560 listed emergency-call systems
Best Application Non-UL installation with separately sourced transformer Transformer-equipped commercial security installation Qualifying UL 2560 emergency-call system

What to Verify Before Ordering

  • Exact model: Confirm that the three-minute EN5040-T is required rather than the EN5040 or EN5040-20T.
  • Transformer requirement: The EN5040-T includes the required transformer.
  • UL application: Verify the complete receiver, transmitter, repeater, power, and panel configuration for the required listing.
  • System compatibility: Confirm that the receiving equipment supports registration and supervision of the EN5040-T.
  • Messaging mode: Determine whether the EchoStream system uses broadcast or directed messaging.
  • Operating frequency: Confirm that the installation requires the North American 902–928 MHz configuration.
  • RF survey: Use an EchoStream survey kit to determine whether a repeater is needed and where it should be mounted.
  • Outdoor installation: Use the compatible ACC650 weatherproof enclosure where appropriate.

Installation and RF Placement Guidance

  • Use an EchoStream site survey to identify weak coverage and determine the optimal repeater location.
  • Mount the repeater away from metal ductwork, wire mesh, pipes, safes, and enclosed metal cabinets.
  • Position the repeater with as few obstacles as possible between it and the receiver, gateway, or other repeaters.
  • Mount the repeater high enough to provide useful line of sight where practical.
  • Design large installations with multiple RF paths to improve system redundancy.
  • Do not mount the repeater to removable surfaces such as suspended-ceiling tiles.
  • Do not connect the transformer to a switch-controlled receptacle.
  • Connect transformer power before connecting the backup battery.
  • Enable and test the wall-tamper and case-tamper mechanisms.
  • Register, supervise, and walk-test the repeater after installation.

Professional installation required: Repeater placement directly affects wireless performance and regulatory compliance. Installation should be completed by a qualified security professional using appropriate EchoStream survey equipment.

Frequently Asked Questions

What does the Inovonics EN5040-T do?

It receives, decodes, and retransmits valid EchoStream wireless messages at enhanced power to extend system coverage.

Does the EN5040-T include a transformer?

Yes. The EN5040-T is supplied with the required transformer. The standard EN5040 does not include one.

Does it include a backup battery?

Yes. It includes a rechargeable lithium-ion backup battery providing approximately 24 hours of typical operation.

How often does the EN5040-T check in?

When registered and supervised, the EN5040-T sends a check-in message every three minutes.

Is the EN5040-T intended for UL 2560 systems?

The EN5040-20T is the 20-minute check-in model identified for qualifying UL 2560 listed emergency-call systems. Verify the complete system requirements before selecting a repeater.

Can multiple EN5040-T repeaters be used?

Yes. Multiple compatible repeaters can be layered throughout a properly designed EchoStream system to expand coverage and provide redundant RF paths.

Does the EN5040-T need to be registered?

It can begin repeating messages after startup, but Inovonics strongly recommends registration and supervision. Registration and supervision are required for applicable UL installations.

Can the EN5040-T be installed outdoors?

The repeater is tested for indoor use. A compatible ACC650 weatherproof enclosure and appropriate installation methods are required for supported outdoor applications.

Does the EN5040-T replace an EchoStream receiver?

No. It extends the wireless path but still requires a compatible EchoStream receiver, gateway, or network coordinator to process the retransmitted messages.

Manufacturer Documents

Inovonics provides a combined installation manual for the EN5040, EN5040-T, and EN5040-20T. Follow the specifications and certifications applicable to the exact repeater model being installed.

A Complete Transformer-Equipped EchoStream Repeater

The Inovonics EN5040-T EchoStream High-Power Repeater with Transformer provides a complete solution for extending wireless coverage throughout multi-floor buildings, campuses, warehouses, shopping centers, and multi-building properties. Its included transformer, rechargeable backup battery, enhanced-power retransmission, layered repeater support, three-minute supervision, RF-jam detection, tamper protection, and applicable security certifications make it a strong choice for professionally designed commercial EchoStream systems.